DOT12-IF-MIB DEFINITIONS ::= BEGIN IMPORTS transmission, Counter32, Counter64, OBJECT-TYPE, MODULE-IDENTITY FROM SNMPv2-SMI MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF ifIndex FROM IF-MIB; dot12MIB MODULE-IDENTITY LAST-UPDATED "9602220452Z" -- February 22, 1996 ORGANIZATION "IETF 100VG-AnyLAN MIB Working Group" CONTACT-INFO " John Flick Postal: Hewlett Packard Company 8000 Foothills Blvd. M/S 5556 Roseville, CA 95747-5556 Tel: +1 916 785 4018 Fax: +1 916 785 3583 E-mail: [email protected]" DESCRIPTION "This MIB module describes objects for managing IEEE 802.12 interfaces." ::= { transmission 45 } dot12MIBObjects OBJECT IDENTIFIER ::= { dot12MIB 1 } dot12ConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot12ConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Configuration information for a collection of 802.12 interfaces attached to a particular system." ::= { dot12MIBObjects 1 } dot12ConfigEntry OBJECT-TYPE SYNTAX Dot12ConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Configuration for a particular interface to an 802.12 medium." INDEX { ifIndex } ::= { dot12ConfigTable 1 } Dot12ConfigEntry ::= SEQUENCE { dot12CurrentFramingType INTEGER, dot12DesiredFramingType INTEGER, dot12FramingCapability INTEGER, dot12DesiredPromiscStatus INTEGER, dot12TrainingVersion INTEGER, dot12LastTrainingConfig OCTET STRING, dot12Commands INTEGER, dot12Status INTEGER, dot12ControlMode INTEGER } dot12CurrentFramingType OBJECT-TYPE SYNTAX INTEGER { frameType88023(1), frameType88025(2), frameTypeUnknown(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "When dot12DesiredFramingType is one of 'frameType88023' or 'frameType88025', this is the type of framing asserted by the interface. When dot12DesiredFramingType is 'frameTypeEither', dot12CurrentFramingType shall be one of 'frameType88023' or 'frameType88025' when the dot12Status is 'opened'. When the dot12Status is anything other than 'opened', dot12CurrentFramingType shall take the value of 'frameTypeUnknown'." ::= { dot12ConfigEntry 1 } dot12DesiredFramingType OBJECT-TYPE SYNTAX INTEGER { frameType88023(1), frameType88025(2), frameTypeEither(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The type of framing which will be requested by the interface during the next interface MAC initialization or open action. In master mode, this is the framing mode which will be granted by the interface. Note that for a master mode interface, this object must be equal to 'frameType88023' or 'frameType88025', since a master mode interface cannot grant 'frameTypeEither'." REFERENCE "IEEE Standard 802.12-1995, 13.2.5.2.1, aDesiredFramingType." ::= { dot12ConfigEntry 2 } dot12FramingCapability OBJECT-TYPE SYNTAX INTEGER { frameType88023(1), frameType88025(2), frameTypeEither(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of framing this interface is capable of supporting." REFERENCE "IEEE Standard 802.12-1995, 13.2.5.2.1, aFramingCapability." ::= { dot12ConfigEntry 3 } dot12DesiredPromiscStatus OBJECT-TYPE SYNTAX INTEGER { singleAddressMode(1), promiscuousMode(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is used to select the promiscuous mode that this interface will request in the next training packet issued on this interface. Whether the repeater grants the requested mode must be verified by examining the state of the PP bits in the corresponding instance of dot12LastTrainingConfig. In master mode, this object controls whether or not promiscuous mode will be granted by the interface when requested by the lower level device. Note that this object indicates the desired mode for the next time the interface trains. The currently active mode will be reflected in dot12LastTrainingConfig and in ifPromiscuousMode." REFERENCE "IEEE Standard 802.12-1995, 13.2.5.2.1, aDesiredPromiscuousStatus." ::= { dot12ConfigEntry 4 } dot12TrainingVersion OBJECT-TYPE SYNTAX INTEGER (0..7) MAX-ACCESS read-only STATUS current DESCRIPTION "The value that will be used in the version bits (vvv bits) in training frames on this interface. This is the highest version number supported by this MAC." REFERENCE "IEEE Standard 802.12-1995, 13.2.5.2.1, aMACVersion." ::= { dot12ConfigEntry 5 } dot12LastTrainingConfig OBJECT-TYPE SYNTAX OCTET STRING (SIZE(2)) MAX-ACCESS read-only STATUS current DESCRIPTION "This 16 bit field contains the configuration bits from the most recent error-free training frame received during training on this interface. Training request frames are received when in master mode, while training response frames are received in slave mode. On master mode interfaces, this object contains the contents of the requested configuration field of the most recent training request frame. On slave mode interfaces, this object contains the contents of the allowed configuration field of the most recent training response frame. The format of the current version of this field is described in section 3.8. Please refer to the most recent version of the IEEE 802.12 standard for the most up-to-date definition of the format of this object." REFERENCE "IEEE Standard 802.12-1995, 13.2.5.2.1, aLastTrainingConfig." ::= { dot12ConfigEntry 6 } dot12Commands OBJECT-TYPE SYNTAX INTEGER { noOp(1), open(2), reset(3), close(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "If the current value of dot12Status is 'closed', setting the value of this object to 'open' will change the corresponding instance of MIB-II's ifAdminStatus to 'up', cause this interface to enter the 'opening' state, and will cause training to be initiated on this interface. The progress and success of the open is given by the values of the dot12Status object. Setting this object to 'open' when dot12Status has a value other than 'closed' has no effect. Setting the corresponding instance of ifAdminStatus to 'up' when the current value of dot12Status is 'closed' will have the same effect as setting this object to 'open'. Setting ifAdminStatus to 'up' when dot12Status has a value other than 'closed' has no effect. Setting the value of this object to 'close' will move this interface into the 'closed' state and cause all transmit and receive actions to stop. This object will then have to be set to 'open' in order to reinitiate training. Setting the corresponding instance of ifAdminStatus to 'down' will have the same effect as setting this object to 'close'. Setting the value of this object to 'reset' when the current value of dot12Status has a value other than 'closed' will reset the interface. On a reset, all MIB counters should retain their values. This will cause the MAC to initiate an acInitializeMAC action as specified in IEEE 802.12. This will cause training to be reinitiated on this interface. Setting this object to 'reset' when dot12Status has a value of 'closed' has no effect. Setting this object to 'reset' has no effect on the corresponding instance of ifAdminStatus. Setting the value of this object to 'noOp' has no effect. When read, this object will always have a value of 'noOp'." REFERENCE "IEEE Standard 802.12-1995, 13.2.5.2.2, acOpen, acClose, acInitializeMAC. Also, RFC1231 IEEE802.5 Token Ring MIB, dot5Commands." ::= { dot12ConfigEntry 7 } dot12Status OBJECT-TYPE SYNTAX INTEGER { opened(1), closed(2), opening(3), openFailure(5), linkFailure(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current interface status with respect to training. One of the following values: opened - Training has completed successfully. closed - MAC has been disabled by setting dot12Commands to 'close'. opening - MAC is in training. Training signals have been received. openFailure - Passed 24 error-free packets, but there is a problem, noted in the training configuration bits (dot12LastTrainingConfig). linkFailure - Training signals not received, or could not pass 24 error-free packets. Whenever the dot12Commands object is set to 'close' or ifAdminStatus is set to 'down', the MAC will go silent, dot12Status will be 'closed', and ifOperStatus will be 'down'. When the value of this object is equal to 'closed' and the dot12Commands object is set to 'open' or the ifAdminStatus object is set to 'up', training will be initiated on this interface. When the value of this object is not equal to 'closed' and the dot12Commands object is set to 'reset', training will be reinitiated on this interface. Note that sets of some other objects (e.g. dot12ControlMode) or external events (e.g. MAC protocol violations) may also cause training to be reinitiated on this interface. When training is initiated or reinitiated on an interface, the end node will send Training_Up to the master and initially go to the 'linkFailure' state and ifOperStatus will go to 'down'. When the master sends back Training_Down, dot12Status will change to the 'opening' state, and training packets will be transferred. After all of the training packets have been passed, dot12Status will change to 'linkFailure' if 24 consecutive error-free packets were not passed, 'opened' if 24 consecutive error-free packets were passed and the training configuration bits were OK, or 'openFailure' if there were 24 consecutive error-free packets, but there was a problem with the training configuration bits. When in the 'openFailure' state, the dot12LastTrainingConfig object will contain the configuration bits from the last training packet which can be examined to determine the exact reason for the training configuration failure. If training did not succeed (dot12Status is 'linkFailure' or 'openFailure), the entire process will be restarted after MAC_Retraining_Delay_Timer seconds. If training does succeed (dot12Status changes to 'opened'), ifOperStatus will change to 'up'. If training does not succeed (dot12Status changes to 'linkFailure' or 'openFailure'), ifOperStatus will remain 'down'." REFERENCE "IEEE Standard 802.12-1995, 13.2.5.2.1, aMACStatus." ::= { dot12ConfigEntry 8 } dot12ControlMode OBJECT-TYPE SYNTAX INTEGER { masterMode(1), slaveMode(2), learn(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is used to configure and report whether or not this interface is operating in master mode. In a Demand Priority network, end node interfaces typically operate in slave mode, while switch interfaces may control the Demand Priority protocol and operate in master mode. This object may be implemented as a read-only object by those agents and interfaces that do not implement software control of master mode. In particular, interfaces that cannot operate in master mode, and interfaces on which master mode is controlled by a pushbutton on the device, should implement this object read-only. Some interfaces do not require network management configuration of this feature and can autosense whether to use master mode or slave mode. The value 'learn' is used for that purpose. While autosense is taking place, the value 'learn' is returned. A network management operation which modifies the value of dot12ControlMode causes the interface to retrain." ::= { dot12ConfigEntry 9 } dot12StatTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot12StatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Statistics for a collection of 802.12 interfaces attached to a particular system." ::= { dot12MIBObjects 2 } dot12StatEntry OBJECT-TYPE SYNTAX Dot12StatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Statistics for a particular interface to an 802.12 medium. The receive statistics in this table apply only to packets received by this station (i.e., packets whose destination address is either the local station address, the broadcast address, or a multicast address that this station is receiving, unless the station is in promiscuous mode)." INDEX { ifIndex } ::= { dot12StatTable 1 } Dot12StatEntry ::= SEQUENCE { dot12InHighPriorityFrames Counter32, dot12InHighPriorityOctets Counter32, dot12InNormPriorityFrames Counter32, dot12InNormPriorityOctets Counter32, dot12InIPMErrors Counter32, dot12InOversizeFrameErrors Counter32, dot12InDataErrors Counter32, dot12InNullAddressedFrames Counter32, dot12OutHighPriorityFrames Counter32, dot12OutHighPriorityOctets Counter32, dot12TransitionIntoTrainings Counter32, dot12HCInHighPriorityOctets Counter64, dot12HCInNormPriorityOctets Counter64, dot12HCOutHighPriorityOctets Counter64 } dot12InHighPriorityFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object is a count of high priority frames that have been received on this interface. Includes both good and bad high priority frames, as well as high priority training frames. Does not include normal priority frames which were priority promoted." REFERENCE "IEEE Standard 802.12-1995, 13.2.5.2.1, aHighPriorityFramesReceived." ::= { dot12StatEntry 1 } dot12InHighPriorityOctets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object is a count of the number of octets contained in high priority frames that have been received on this interface. This counter is incremented by OctetCount for each frame received on this interface which is counted by dot12InHighPriorityFrames. Note that this counter will roll over very quickly. It is provided for backward compatibility for Network Management protocols that do not support 64 bit counters (e.g. SNMP version 1)." REFERENCE "IEEE Standard 802.12-1995, 13.2.5.2.1, aHighPriorityOctetsReceived." ::= { dot12StatEntry 2 } dot12InNormPriorityFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object is a count of normal priority frames that have been received on this interface. Includes both good and bad normal priority frames, as well as normal priority training frames and normal priority frames which were priority promoted." REFERENCE "IEEE Standard 802.12-1995, 13.2.5.2.1, aNormalPriorityFramesReceived." ::= { dot12StatEntry 3 } dot12InNormPriorityOctets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object is a count of the number of octets contained in normal priority frames that have been received on this interface. This counter is incremented by OctetCount for each frame received on this interface which is counted by dot12InNormPriorityFrames. Note that this counter will roll over very quickly. It is provided for backward compatibility for Network Management protocols that do not support 64 bit counters (e.g. SNMP version 1)." REFERENCE "IEEE Standard 802.12-1995, 13.2.5.2.1, aNormalPriorityOctetsReceived." ::= { dot12StatEntry 4 } dot12InIPMErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object is a count of the number of frames that have been received on this interface with an invalid packet marker and no PMI errors. A repeater will write an invalid packet marker to the end of a frame containing errors as it is forwarded through the repeater to the other ports. This counter is incremented by one for each frame received on this interface which has had an invalid packet marker added to the end of the frame." REFERENCE "IEEE Standard 802.12-1995, 13.2.5.2.1, aIPMFramesReceived." ::= { dot12StatEntry 5 } dot12InOversizeFrameErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object is a count of oversize frames received on this interface. This counter is incremented by one for each frame received on this interface whose OctetCount is larger than the maximum legal frame size. The frame size which causes this counter to increment is dependent on the current framing type." REFERENCE "IEEE Standard 802.12-1995, 13.2.5.2.1, aOversizeFramesReceived." ::= { dot12StatEntry 6 } dot12InDataErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object is a count of errored frames received on this interface. This counter is incremented by one for each frame received on this interface with any of the following errors: bad FCS (with no IPM), PMI errors (excluding frames with an IPM as the only PMI error), undersize, bad start of frame delimiter, or bad end of packet marker. Does not include frames counted by dot12InIPMErrors, dot12InNullAddressedFrames, or dot12InOversizeFrameErrors. This counter indicates problems with the cable directly attached to this interface, while dot12InIPMErrors indicates problems with remote cables." REFERENCE "IEEE Standard 802.12-1995, 13.2.5.2.1, aDataErrorFramesReceived." ::= { dot12StatEntry 7 } dot12InNullAddressedFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object is a count of null addressed frames received on this interface. This counter is incremented by one for each frame received on this interface with a destination MAC address consisting of all zero bits. Both void and training frames are included in this counter. Note that since this station would normally not receive null addressed frames, this counter is only incremented when this station is operating in promiscuous mode or in training." REFERENCE "IEEE Standard 802.12-1995, 13.2.5.2.1, aNullAddressedFramesReceived." ::= { dot12StatEntry 8 } dot12OutHighPriorityFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is incremented by one for each high priority frame successfully transmitted out this interface." REFERENCE "IEEE Standard 802.12-1995, 13.2.5.2.1, aHighPriorityFramesTransmitted." ::= { dot12StatEntry 9 } dot12OutHighPriorityOctets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is incremented by OctetCount for each frame counted by dot12OutHighPriorityFrames. Note that this counter will roll over very quickly. It is provided for backward compatibility for Network Management protocols that do not support 64 bit counters (e.g. SNMP version 1)." REFERENCE "IEEE Standard 802.12-1995, 13.2.5.2.1, aHighPriorityOctetsTransmitted." ::= { dot12StatEntry 10 } dot12TransitionIntoTrainings OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object is a count of the number of times this interface has entered the training state. This counter is incremented by one each time dot12Status transitions to 'linkFailure' from any state other than 'opening' or 'openFailure'." REFERENCE "IEEE Standard 802.12-1995, 13.2.5.2.1, aTransitionsIntoTraining." ::= { dot12StatEntry 11 } dot12HCInHighPriorityOctets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "This object is a count of the number of octets contained in high priority frames that have been received on this interface. This counter is incremented by OctetCount for each frame received on this interface which is counted by dot12InHighPriorityFrames. This counter is a 64 bit version of dot12InHighPriorityOctets. It should be used by Network Management protocols which support 64 bit counters (e.g. SNMPv2)." REFERENCE "IEEE Standard 802.12-1995, 13.2.5.2.1, aHighPriorityOctetsReceived." ::= { dot12StatEntry 12 } dot12HCInNormPriorityOctets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "This object is a count of the number of octets contained in normal priority frames that have been received on this interface. This counter is incremented by OctetCount for each frame received on this interface which is counted by dot12InNormPriorityFrames. This counter is a 64 bit version of dot12InNormPriorityOctets. It should be used by Network Management protocols which support 64 bit counters (e.g. SNMPv2)." REFERENCE "IEEE Standard 802.12-1995, 13.2.5.2.1, aNormalPriorityOctetsReceived." ::= { dot12StatEntry 13 } dot12HCOutHighPriorityOctets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is incremented by OctetCount for each frame counted by dot12OutHighPriorityFrames. This counter is a 64 bit version of dot12OutHighPriorityOctets. It should be used by Network Management protocols which support 64 bit counters (e.g. SNMPv2)." REFERENCE "IEEE Standard 802.12-1995, 13.2.5.2.1, aHighPriorityOctetsTransmitted." ::= { dot12StatEntry 14 } -- conformance information dot12Conformance OBJECT IDENTIFIER ::= { dot12MIB 2 } dot12Compliances OBJECT IDENTIFIER ::= { dot12Conformance 1 } dot12Groups OBJECT IDENTIFIER ::= { dot12Conformance 2 } -- compliance statements dot12Compliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for managed network entities that have 802.12 interfaces." MODULE -- this module MANDATORY-GROUPS { dot12ConfigGroup, dot12StatsGroup } OBJECT dot12DesiredFramingType MIN-ACCESS read-only DESCRIPTION "Write access to this object is not required." OBJECT dot12DesiredPromiscStatus MIN-ACCESS read-only DESCRIPTION "Write access to this object is not required." OBJECT dot12Commands MIN-ACCESS read-only DESCRIPTION "Write access to this object is not required." OBJECT dot12ControlMode MIN-ACCESS read-only DESCRIPTION "Write access to this object is not required." ::= { dot12Compliances 1 } -- units of conformance dot12ConfigGroup OBJECT-GROUP OBJECTS { dot12DesiredFramingType, dot12FramingCapability, dot12DesiredPromiscStatus, dot12TrainingVersion, dot12LastTrainingConfig, dot12Commands, dot12Status, dot12CurrentFramingType, dot12ControlMode } STATUS current DESCRIPTION "A collection of objects for managing the status and configuration of IEEE 802.12 interfaces." ::= { dot12Groups 1 } dot12StatsGroup OBJECT-GROUP OBJECTS { dot12InHighPriorityFrames, dot12InHighPriorityOctets, dot12InNormPriorityFrames, dot12InNormPriorityOctets, dot12InIPMErrors, dot12InOversizeFrameErrors, dot12InDataErrors, dot12InNullAddressedFrames, dot12OutHighPriorityFrames, dot12OutHighPriorityOctets, dot12TransitionIntoTrainings, dot12HCInHighPriorityOctets, dot12HCInNormPriorityOctets, dot12HCOutHighPriorityOctets } STATUS current DESCRIPTION "A collection of objects providing statistics for IEEE 802.12 interfaces." ::= { dot12Groups 2 } END